The PharmEasy Smart Blood Pressure Monitor (Model OBP-117) is an automatic upper arm blood pressure monitor meant to be used by adults to measure systolic and diastolic blood pressure and pulse rate.
The device uses the oscillometric method to detect blood movement through the brachial artery and converts it into digital readings. It supports connectivity with the PharmEasy app, allowing users to pair the device, store and track their readings over time, and access AI-powered insights in the app. Other features include memory storage, automatic measurement, and blood pressure classification display. The pack includes a cuff, main unit, and instruction manual.
Benefits
Measures systolic and diastolic blood pressure to help you monitor your cardiovascular health
Measures pulse rate alongside blood pressure for a more comprehensive health assessment
Stores measurement results thanks to the app syncing feature, helping you track trends, compare readings, and gain meaningful insights
Displays blood pressure classification to help with better interpretation of the results
Enables repeated measurements for monitoring
How to Use
Keep quiet for 5-10 minutes before measurement
Avoid eating, drinking alcohol, smoking, exercising, or bathing before use
Remove tight clothing from the upper arm
Wrap the cuff around the upper arm, approximately 2-3 cm above the elbow
Ensure the cuff is snug and positioned correctly
Keep the arm at heart level and remain still
Press the START/STOP button to begin measurement
Wait until the measurement is completed and the results are displayed
Safety and Storage Information
Clean with a soft dry cloth
Do not use abrasive or volatile cleaners
Do not immerse in water
Store in a clean, dry place
Avoid extreme temperatures, humidity, and direct sunlight
Remove batteries if not used for more than 3 months
Precautions and Warnings
Use only under a physician's instruction if you have arrhythmia, diabetes, or circulation problems
Do not self-diagnose or self-treat based on results
Keep the device out of reach of children
Do not modify the equipment
Use only the provided cuff
Avoid using near flammable gases or strong electromagnetic fields
Do not mix old and new batteries
Remove batteries if not in use for extended periods
Error Indicators and Troubleshooting
E-1: Weak signal or pressure change - wrap cuff properly and remeasure
E-2: External disturbance - keep quiet and avoid interference
E-3: Inflation error - ensure air plug is properly inserted, and cuff is correctly wrapped
E-4: Abnormal blood pressure - repeat measurement after rest
Low battery symbol: Replace batteries
FAQ
Q1: What measurement method does the device use?
Ans: The device uses the oscillometric method to measure blood pressure. It detects blood movement through the brachial artery during cuff inflation and deflation, and converts these signals into digital readings for systolic pressure, diastolic pressure, and pulse rate. This method does not require a stethoscope.
Q2: What parameters does the device measure?
Ans: The monitor measures three key parameters: systolic blood pressure (upper value), diastolic blood pressure (lower value), and pulse rate (heartbeats per minute). These values are displayed digitally on the screen after each measurement.
Q3: What is the memory capacity of the device?
Ans: The device can store up to 2 × 90 measurement readings. This allows two users to store and track their readings separately over time for reference and comparison.
Q4: What is the correct way to wear the cuff?
Ans: The cuff should be wrapped around the upper arm, approximately 2-3 cm above the elbow. It should be snug but not too tight, and positioned so that the air tube runs down the arm. Proper placement is essential to ensure accurate readings.
Q5: What precautions should be taken before measuring blood pressure?
Ans: Before taking a measurement, rest for 5-10 minutes and remain calm. Avoid eating, smoking, consuming alcohol, exercising, or bathing immediately before measurement. Sit comfortably, keep your back supported, feet flat on the ground, and your arm at heart level.
Q6: Can the device be used without connecting to the mobile app?
Ans: Yes, the device can be used independently without the mobile app. All measurements will be displayed on the device screen and stored in its internal memory. The app is optional and is used for tracking and reviewing data.
Q7: What do the error codes (E-1, E-2, E-3, E-4) indicate?
Ans:
E-1: Weak signal or improper cuff wrapping
E-2: External disturbance such as movement or interference
E-3: Inflation error due to improper cuff connection
E-4: Abnormal measurement detected
If any error appears, check cuff placement, remain still, and repeat the measurement.
Q8: What causes inaccurate readings?
Ans: Inaccurate readings may result from incorrect cuff placement, movement during measurement, talking, improper posture, or external interference such as nearby electronic devices. Ensuring proper positioning and remaining still improves accuracy.
Q9: Who should use this blood pressure monitor?
Ans: The device is intended for use by adults to monitor blood pressure and pulse rate. Individuals with specific medical conditions such as arrhythmia, diabetes, or circulation disorders should use the device under medical guidance.
Q10: How should the device be maintained and stored?
Ans: The device should be cleaned with a soft, dry cloth and should not be exposed to water or harsh cleaning agents. Store it in a cool, dry place away from direct sunlight, extreme temperatures, and humidity. Remove batteries if the device will not be used for an extended period.